suntrenz skylights

Tackling Roof Cavity Moisture Across a 77-Apartment Development

Suntrenz was approached after significant moisture, condensation and mould issues were identified within the ceiling cavities of a relatively new development comprising 77 two-storey apartments.

The apartments had very low-pitch roofs of approximately 3–5 degrees, with relatively small and confined roof cavities. Testing identified highly elevated moisture levels within the roof spaces, with visible mould spotting beginning to form on sections of the building roof underlay.

With the issue affecting multiple apartments, a retrofit solution was required that could create controlled airflow through the roof cavities while integrating reliably with the existing roofing system.

To protect the privacy of those involved, the developer, builder and project location have not been identified.

Vent for ceiling cavity ventilation in an apartment complex

How Roof Design Affects Roof Cavity Ventilation and Moisture

Modern New Zealand homes are increasingly well insulated and airtight. While this is positive for energy efficiency, moisture generated inside a home can still find its way into the roof cavity through ceiling penetrations and other air leakage paths.

From the buildings Suntrenz has inspected, we have observed that low-pitch roofs with smaller roof cavities appear more susceptible to moisture build-up where there is limited natural air movement. Conversely, buildings with larger roof cavities and higher roof pitches have generally presented fewer of these moisture-related issues.

This is a field observation rather than a rule that applies to every home. Roof cavity moisture can be influenced by indoor humidity, ceiling airtightness, insulation, ventilation, roof design and external conditions.

In this development, the combination of a 3–5° roof pitch, a small roof cavity and elevated moisture made creating purposeful airflow through the roof space an important part of the proposed solution.

ventilation installed in the roof cavity of a home to reduce moisture

Suntrenz roof cavity ventilation system

Drawing on our experience with roof penetrations, ventilation and New Zealand roofing systems, Suntrenz developed a dedicated retrofit roof cavity ventilation system.

Each system uses two purpose-made 150mm Suntrenz roof penetrations. One provides a dedicated fresh-air inlet, while the second is connected to a mechanically powered extraction system located within the roof cavity.

Rather than relying solely on passive ventilation, the system creates purposeful air exchange through the confined roof space: fresh outside air is introduced through the inlet while moisture-laden cavity air is mechanically extracted through the outlet.

The system is timer controlled, allowing it to operate during selected periods of the day rather than continuously.

Ventilation installed in the roof cavity of apartments to reduce moisture

Testing the Roof Cavity Ventilation Solution

Before installing the system throughout the development, Suntrenz trialled the roof cavity ventilation system in one of the worst-affected apartments. Testing showed highly elevated moisture levels within the roof cavity, along with visible signs of mould developing on the building underlay.

One ventilation system was installed and programmed to operate for approximately six hours per day. After seven days, the roof cavity was tested again, with moisture levels having dropped significantly and returning to acceptable levels.

Following review of the trial results, approval was given to proceed with the wider installation across the development. The original numerical moisture readings are not held by Suntrenz, so specific moisture percentages have not been included in this case study.

Up to 2,430 m³ of Air Capacity Per Day

The mechanical extraction system used on this project has a free-air capacity of up to 405 m³ per hour (112.5 L/sec).

At approximately six hours of scheduled operation per day, that provides a theoretical free-air capacity of up to 2,430 m³ per day, creating deliberate air exchange through the roof cavity and helping provide the roof space with an opportunity to dry.

Successful installation

Following the successful initial trial, Suntrenz was given approval to install the system throughout the development.

77

Apartments

144

Vents

2,430 m³

AIR CAPACITY / DAY